Sys.CfgSetValue
This command stores a value in the reader's configuration. The
Content parameter will be stored to the desired
configuration value specified by the Key and Value
parameters. If the value is already stored in the
configuration, it will be replaced.
Properties
- Command code: 0x0009
- Command timeout: 10000 ms
- Possible status codes: General status codes, Sys.ErrCfgNotFound , Sys.ErrCfgAccess, Sys.ErrCfgFull, Sys.ErrCfgAccessDenied
Parameters (request frame)
Name | Type/Size | Description |
---|---|---|
Key | Integer (16 bits) | - |
Value | Integer (8 bits) | - |
Length of Content | Integer (8 bits) |
Length of Content in bytes |
Content | Raw data | Content to write as configuration value (maximal allowed length: 0x80). |
Returned values (response frame)
None